Zhufeng ACI General Frequency Inverter DLT-G11
ͨÓÃÐÍ±äÆµÆ÷DLT-G11
¡¾¹¦ÂÊ·¶Î§£º0.4KW-800KW¡¿
¼¼ÊõÌØµã¼°¹¦ÄÜ£º
¢ÙÈýÖÖËÙ¶È¿ØÖÆ·½Ê½£ºÎÞPGʸÁ¿¿ØÖÆ¡¢ÓÐPGʸÁ¿¿ØÖÆ¡¢V/F¿ØÖÆ·½Ê½£»
¢ÚÌṩ¿ÉÑ¡µÄLED¿ØÖÆÃæ°å£¬¾ßÓÐSVPWM¿ØÖƹ¦ÄܼÆÊý¡¢ÌøÆµ¹¦ÄÜ£»
¢Û16¶Î¼òÒ×PLC£¬¶à¶ÎËٶȼ°PID¿ØÖÆ£»°ÚƵ¹¦ÄÜ£»
¢Ü˲¼äµôµç²»Í£»ú£¬×ªËÙ×·×ÙÔÙÆð¶¯£¬×Ô¶¯µçѹµ÷Õû£»
¢ÝÌṩRS485ÎïÀíͨѶ¶Ë×Ó½Ó¿Ú£¬²ÉÓñê×¼ModbusÐÒ飬·½±ã×éÍø£¬ÊµÏÖÉÏλ»ú¼à¿Ø£»
¢ÞÌṩ¶à¹¦ÄÜ6·Êý×ÖÁ¿ÊäÈ룬1·¸ßËÙÂö³åÊäÈ룬2·ģÄâÁ¿ÊäÈ룬2·¼ÌµçÆ÷Êä³ö£¨2.2KWÒÔÏÂ1 ·£©1·ģÄâÁ¿Êä³ö£»
1.ÌØÉ«¹¦ÄÜ£º×Ô¶¯½ÚÄÜ¡¢¼ì²â¸ºÔØÌØÐÔµ÷Õû×î¼ÑÊä³ö״̬
2.À©Õ¹¹¦ÄÜ£º¿ÉÁ¿Éí¶©ÖÆ±äƵÆ÷½Úµç¹ñ
Ó¦ÓÃÐÐÒµ£º
1.Ò±½ð¡¢µçÁ¦¡¢Ê¯»¯¡¢Ë®Äà¡¢²É¿ó¡¢½¨²Ä¡¢ÖÆÒ©¡¢ÔìÖ½¡¢ËÜÁÏ
2.¹øÂ¯ËÍ·ç»ú¡¢Ãº¿óÅÅ·ç»ú¡¢ÅÅÆøËÍ·ç¿ØÖÆ¡¢Ë®´¦Àí¿ØÖÆ
3.¾«È·¶¨Î»¿ØÖÆÏµÍ³¡¢ÁãËÅ·þϵͳ¡¢ÔìÖ½¡¢»¯ÏËÉú²úÏß¡¢°ü×°¡¢»úе
4.Ìմɳ§¡¢»¯¹¤³§¡¢ÓÍÌïÓͳ§¡¢ÆÆËé»ú¡¢Ñ¹Öý»ú¡¢Ñ¹Ëõ»ú
²úÆ·¼¼Êõ¹æ·¶£º
ÏîÄ¿ | ±ê×¼¹æ·¶ | |
ÊäÈë | ¶î¶¨µçѹ/ƵÂÊ | µ¥Ïà220V¡¢ÈýÏà220V¡¢ÈýÏà 380V£»50Hz/60Hz |
±ä¶¯ÈÝÐíÖµ | µçѹ£º-20% ¡« +20£¥ µçѹʧºâÂÊ£º<3% ƵÂÊ£º¡À10£¥ | |
Êä³ö | ¶î¶¨µçѹ | 0¡«220V/380V |
ƵÂÊ·¶Î§ | 0Hz¡«500Hz | |
ƵÂʽâÎö¶È | 0.01Hz | |
¹ýÔØÄÜÁ¦ | ¶î¶¨µçÁ÷¡Á150%1·Ö | |
Ö÷Òª¿ØÖƹ¦ÄÜ | µ÷ÖÆ·½Ê½ | ÓÅ»¯¿Õ¼äµçѹʸÁ¿SVPWMµ÷ÖÆ |
¿ØÖÆ·½Ê½ | ÎÞPGʸÁ¿¿ØÖÆ¡¢ÓÐPGʸÁ¿¿ØÖÆ¡¢V/F¿ØÖÆ | |
ƵÂʾ«¶È | Êý×ÖÉ趨£º×î¸ßƵÂÊ¡Á¡À0. 01%£»Ä£ÄâÉ趨£º×î¸ßƵÂÊ¡Á¡À0.2% | |
ƵÂÊ·Ö±æÂÊ | Êý×ÖÉ趨£º0.01Hz£»Ä£ÄâÉ趨£º×î¸ßƵÂÊ¡Á0.1% | |
Æð¶¯ÆµÂÊ | 0.40Hz¡«20.00Hz | |
ת¾ØÌáÉý | ×Ô¶¯×ª¾ØÌáÉý£¬ÊÖ¶¯×ª¾ØÌáÉý0.1%¡«30.0% | |
V/FFFFFÇúÏß | ÎåÖÖ·½Ê½£ººãת¾ØV/FÇúÏß¡¢1ÖÖÓû§¶¨Òå¶à¶ÎV/FÇúÏß·½Ê½ºÍ3ÖÖ½µ×ª¾ØÌØÐÔÇúÏß·½Ê½(2.0´ÎÃÝ¡¢1.7´ÎÃݺÍ1.2´ÎÃÝ) | |
¼Ó¼õËÙÇúÏß | Á½ÖÖ·½Ê½£ºÖ±Ïß¼Ó¼õËÙ¡¢SÇúÏß¼Ó¼õËÙ£»ÆßÖÖ¼Ó¼õËÙʱ¼ä£¬Ê±¼äµ¥Î»(·Ö/Ãë)¿ÉÑ¡ £¬×6000·ÖÖÓ | |
Ö±Á÷ÖÆ¶¯ | Ö±Á÷ÖÆ¶¯¿ªÊ¼ÆµÂÊ£º0¡«15.00Hz ÖÆ¶¯Ê±¼ä£º0¡«60.0Ãë ÖÆ¶¯µçÁ÷£º0¡«80£¥ | |
ÄܺÄÖÆ¶¯ | ÄÚÖÃÄܺÄÖÆ¶¯µ¥Ôª£¬¿ÉÍâ½ÓÖÆ¶¯µç×è | |
µã¶¯ | µã¶¯ÆµÂÊ·¶Î§£º0.1Hz¡«50.00Hz,µã¶¯¼Ó¼õËÙʱ¼ä0.1¡«60.0Ãë | |
ÄÚÖÃPI | ¿É·½±ãµØ¹¹³É±Õ»·¿ØÖÆÏµÍ³ | |
¶à¶ÎËÙÔËÐÐ | ͨ¹ýÄÚÖÃPLC»ò¿ØÖƶË×ÓʵÏÖ¶à¶ÎËÙÔËÐÐ | |
·ÄÖ¯°ÚƵ | ¿ÉʵÏÖÔ¤ÖÃÆµÂÊ¡¢ÖÐÐÄÆµÂʿɵ÷µÄ°ÚƵ¹¦ÄÜ | |
×Ô¶¯µçѹµ÷Õû(AVR) | µ±µçÍøµçѹ±ä»¯Ê±£¬Î¬³ÖÊä³öµçѹºã¶¨²»±ä | |
×Ô¶¯½ÚÄÜÔËÐÐ | ¸ù¾Ý¸ºÔØÇé¿ö£¬×Ô¶¯ÓÅ»¯V/FÇúÏߣ¬ÊµÏÖ½ÚÄÜÔËÐÐ | |
×Ô¶¯ÏÞÁ÷ | ¶ÔÔËÐÐÆÚ¼äµçÁ÷×Ô¶¯ÏÞÖÆ£¬·ÀֹƵ·±¹ýÁ÷¹ÊÕÏÌøÕ¢ | |
¶¨³¤¿ØÖÆ | µ½´ïÉ趨³¤¶Èºó±äƵÆ÷Í£»ú | |
ͨѶ¹¦ÄÜ | ¾ßÓÐRS485±ê׼ͨѶ½Ó¿Ú£¬Ö§³ÖASCIIºÍRTUÁ½ÖÖ¸ñʽµÄMODBUSͨѶÐÒé¡£¾ßÓÐÖ÷´Ó¶à»úÁª¶¯¹¦ÄÜ | |
ÏîÄ¿ | ±ê×¼¹æ·¶ | |
ÔËÐй¦ÄÜ | ÔËÐÐÃüÁîͨµÀ | ²Ù×÷Ãæ°å¸ø¶¨£»¿ØÖƶË×Ó¸ø¶¨£»´®Ðпڸø¶¨£»¿ÉÈýÖÖ·½Ê½Çл» |
ƵÂÊÉ趨ͨµÀ | ¼üÅÌÄ£ÄâµçλÆ÷¸ø¶¨£»¼üÅÌ¡ø¡¢¨‹¼ü¸ø¶¨£»¹¦ÄÜÂëÊý×Ö¸ø¶¨£»´®Ðпڸø¶¨£»¶Ë×ÓUP/DOWN¸ø¶¨£»Ä£Äâµçѹ¸ø¶¨£»Ä£ÄâµçÁ÷¸ø¶¨£»Âö³å¸ø¶¨£»×éºÏ¸ø¶¨£»¿É¶àÖÖ¸ø¶¨·½Ê½ËæÊ±Çл» | |
¿ª¹ØÊäÈëͨµÀ | Õý¡¢·´×ªÖ¸Á8·¿É±à³Ì¿ª¹ØÁ¿ÊäÈ룬¿É·Ö±ðÉ趨35ÖÖ¹¦ÄÜ¡£ | |
Ä£ÄâÊäÈëͨµÀ | 2·ģÄâÐźÅÊäÈ룬4¡«20mA¡¢0¡«10V¿ÉÑ¡ | |
Ä£ÄâÊä³öͨµÀ | Ä£ÄâÐźÅÊä³ö£¬ 4¡«20mA»ò0¡«10V¿ÉÑ¡£¬¿ÉʵÏÖÉ趨ƵÂÊ¡¢Êä³öƵÂʵÈÎïÀíÁ¿µÄÊä³ö | |
¿ª¹Ø¡¢Âö³åÊä³öͨ µÀ | 1·¿É±à³Ì¿ªÂ·¼¯µç¼«Êä³ö£»1·¼ÌµçÆ÷Êä³öÐźţ»1·0¡«20KHzÂö³åÊä³öÐźţ¬ÊµÏÖ¸÷ÖÖÎïÀíÁ¿Êä³ö | |
²Ù×÷ Ãæ°å | LEDÊýÂëÏÔʾ | ¿ÉÏÔʾÉ趨ƵÂÊ¡¢Êä³öµçѹ¡¢Êä³öµçÁ÷µÈ²ÎÊý |
Íâ½ÓÒDZíÏÔʾ | Êä³öƵÂÊ¡¢Êä³öµçÁ÷¡¢Êä³öµçѹÏÔʾµÈÎïÀíÁ¿ÏÔʾ | |
°´¼üËø¶¨ | ʵÏÖ°´¼üµÄÈ«²¿Ëø¶¨ | |
²ÎÊý¿½±´ | ʹÓÃÔ¶¿Ø¼üÅÌ¿ÉÒÔʵÏֱ䯵Æ÷Ö®¼äµÄ¹¦ÄÜÂë²ÎÊý¿½±´¹¦ÄÜ¡£ | |
±£»¤¹¦ÄÜ | ¹ýÁ÷±£»¤£»¹ýѹ±£»¤£»Ç·Ñ¹±£»¤£»¹ýÈȱ£»¤£»¹ýÔØ±£»¤µÈ | |
ÈÎÑ¡¼þ | ÖÆ¶¯×é¼þ£»Ô¶³Ì²Ù×÷Ãæ°å£»Ô¶³ÌµçÀ£»¼üÅ̰²×°×ùµÈ | |
»·¾³ | ʹÓó¡Ëù | ÊÒÄÚ£¬²»ÊÜÑô¹âÖ±É䣬ÎÞ³¾°£¡¢¸¯Ê´ÐÔÆøÌå¡¢ÓÍÎí¡¢Ë®ÕôÆûµÈ |
º£²¨¸ß¶È | µÍÓÚ1000Ã×£¨¸ßÓÚ1000Ã×ʱÐè½µ¶îʹÓã© | |
»·¾³ÎÂ¶È | £10¡æ¡«£«40¡æ | |
ʪ¶È | СÓÚ90%RH£¬Î޽ᶠ| |
Õñ¶¯ | СÓÚ5.9Ã×/Ãë2£¨0.6G£© | |
´æ´¢ÎÂ¶È | £20¡æ¡«£«60¡æ | |
½á¹¹ | ·À»¤µÈ¼¶ | IP20£¨ÔÚÑ¡ÓÃ״̬ÏÔʾµ¥Ôª»ò¼üÅ̵Ä״̬Ï£© |
ÀäÈ´·½Ê½ | Ç¿ÖÆ·çÀä | |
°²×°·½Ê½ | ±Ú¹Òʽ£¬¹ñÄÚ°²×° |
Ãæ°å²Ù×÷ͼ£º
ÍâÐγߴ磺
¹«Ë¾×Ü»ú£º020-28608999
¹«Ë¾´«Õ棺020-28008900

- Technical Parameters:
Zhufeng ACI General Frequency Inverter DLT-G11
¡¾Power Range: 0.4KW-800KW¡¿
Technical features and functions:
¢Ù three speed control: non PG vector control, PG vector control, V / F control;
¢Ú provides an optional LED control panel, with SVPWM control function counting, frequency hopping function;
¢Û 16 simple PLC, multi-speed and PID control; wobble frequency function;
¢Ü instantaneous power-down non-stop, speed tracking and then start, automatic voltage adjustment;
¢Ý RS485 physical communication interface to provide the use of standard Modbus protocol to facilitate networking, to achieve PC monitoring;
¢Þ provide multi-function 6-channel digital input, a high-speed pulse input, 2 analog inputs, 2 relay output (2.2KW following 1) 1 analog output;
1. Features: Automatic energy-saving, load characteristics to adjust the best detection of the output state
2. Extended functions: can be tailored inverter energy-saving cabinet
Application Industry:
1. Metallurgy, power, petrochemical, cement, mining, building materials, pharmaceutical, paper, plastic
2. Boiler blower, coal mine exhaust fan, exhaust air control, water treatment control
3. Precise positioning control system, zero servo system, paper, chemical fiber production lines, packaging, machinery
4. Ceramic factories, chemical plants, oil refineries, crushers, die-casting machines, compressors
Specification:
ÏîÄ¿project
±ê×¼¹æ·¶standard specification
ÊäÈëinput
¶î¶¨µçѹ/ƵÂÊRated voltage / frequency
µ¥Ïà220V¡¢ÈýÏà220V¡¢ÈýÏà 380V£»50Hz/60Hz
Single-phase 220V, three phase 220V, three phase 380V; 50Hz / 60Hz
±ä¶¯ÈÝÐíÖµChange allowable value
µçѹ£º-20% ¡« +20£¥ µçѹʧºâÂÊ£º<3% ƵÂÊ£º¡À10£¥
Voltage: -20% to + 20% voltage unbalance rate: <3% Frequency: ¡À 10%
Êä³öoutput
¶î¶¨µçѹ
Rated voltage
0¡«220V/380V/
ƵÂÊ·¶Î§frequency range
0Hz¡«500Hz
ƵÂʽâÎö¶ÈFrequency resolution
0.01Hz
¹ýÔØÄÜÁ¦Overload capacity
P:120%IN, G:150% IN QF¡¢Z¡¢L: 180% IN 1·ÖÖÓ 1 minute
Ö÷Òª¿ØÖƹ¦ÄÜMain control function
µ÷ÖÆ·½Ê½modulation mode
ÓÅ»¯¿Õ¼äµçѹʸÁ¿SVPWMµ÷ÖÆOptimized space voltage vector SVPWM modulation
¿ØÖÆ·½Ê½control mode
¿Õ¼äµçѹʸÁ¿SVPWM¿ØÖÆ£¨¾ßÓÐ×îÓÅµÍÆµËÀÇø²¹³¥ÌØÐÔ£©Space voltage vector SVPWM control (with optimal low frequency dead zone compensation characteristic)
ƵÂʾ«¶ÈFrequency accuracy
Êý×ÖÉ趨£º×î¸ßƵÂÊ¡Á¡À0. 01%£»Ä£ÄâÉ趨£º×î¸ßƵÂÊ¡Á¡À0.2%
Digital setting: the maximum frequency is 0.01%; the simulation setting: the maximum frequency is 0.2%.
ƵÂÊ·Ö±æÂÊfrequency resolution
Êý×ÖÉ趨£º0.01Hz£»Ä£ÄâÉ趨£º×î¸ßƵÂÊ¡Á0.1%
Digital setting: 0.01Hz; simulation setting: maximum frequency x 0.1%
Æð¶¯ÆµÂÊStarting frequency
0.40Hz¡«20.00Hz
ת¾ØÌáÉýTorque boost
×Ô¶¯×ª¾ØÌáÉý£¬ÊÖ¶¯×ª¾ØÌáÉý0.1%¡«30.0%
Automatic torque promotion, manual torque increased by 0.1% ~ 30%
V/FFFFFÇúÏßV/F curve
ÎåÖÖ·½Ê½£ººãת¾ØV/FÇúÏß¡¢1ÖÖÓû§¶¨Òå¶à¶ÎV/FÇúÏß·½Ê½ºÍ3ÖÖ½µ×ª¾ØÌØÐÔÇúÏß·½Ê½(2.0´ÎÃÝ¡¢1.7´ÎÃݺÍ1.2´ÎÃÝ)Five ways: constant torque V/F curve, 1 kinds of user defined multi segment V/F curve mode and 3 kinds of down torque characteristic curve mode (2 power, 1.7 power and 1.2 power)
¼Ó¼õËÙÇúÏßAcceleration and deceleration curve
Á½ÖÖ·½Ê½£ºÖ±Ïß¼Ó¼õËÙ¡¢SÇúÏß¼Ó¼õËÙ£»ÆßÖÖ¼Ó¼õËÙʱ¼ä£¬Ê±¼äµ¥Î»(·Ö/Ãë)¿ÉÑ¡ £¬×6000·ÖÖÓTwo ways: linear acceleration and deceleration, S curve acceleration and deceleration; seven plus deceleration time, time unit (sub / sec) optional, the longest 6000 minutes
Ö±Á÷ÖÆ¶¯DC braking
Ö±Á÷ÖÆ¶¯¿ªÊ¼ÆµÂÊ£º0¡«15.00Hz
DC brake starting frequency: 0 ~ 15.00Hz
ÖÆ¶¯Ê±¼ä£º0¡«60.0ÃëBraking time: 0.0s ~ 60.0s
ÖÆ¶¯µçÁ÷£º0¡«80£¥Brake current: 0 ~ 80%
ÄܺÄÖÆ¶¯Energy consumption braking
ÄÚÖÃÄܺÄÖÆ¶¯µ¥Ôª£¬¿ÉÍâ½ÓÖÆ¶¯µç×èBuilt in energy consumption braking unit, and can be externally connected with brake resistance.
µã¶¯Jog
µã¶¯ÆµÂÊ·¶Î§£º0.1Hz¡«50.00Hz,µã¶¯¼Ó¼õËÙʱ¼ä0.1¡«60.0ÃëJog Frequency range: 0.1Hz ~ 50.00Hz, Jog acceleration and deceleration time of 0.1 to 60.0 seconds
ÄÚÖÃPID
Built in PID
¿É·½±ãµØ¹¹³É±Õ»·¿ØÖÆÏµÍ³
Closed loop control system can be easily formed
¶à¶ÎËÙÔËÐÐMulti speed operation
ͨ¹ýÄÚÖÃPLC»ò¿ØÖƶË×ÓʵÏÖ¶à¶ÎËÙÔËÐÐThrough the built-in PLC or control terminal to achieve multi speed operation
·ÄÖ¯°ÚƵTextile oscillation
frequency
¿ÉʵÏÖÔ¤ÖÃÆµÂÊ¡¢ÖÐÐÄÆµÂʿɵ÷µÄ°ÚƵ¹¦ÄÜ
Can achieve preset frequency, center frequency adjustable swing function
×Ô¶¯µçѹµ÷Õû(AVR)Automatic voltage regulation (AVR)
µ±µçÍøµçѹ±ä»¯Ê±£¬Î¬³ÖÊä³öµçѹºã¶¨²»±ä
When the grid voltage is changed, the output voltage is kept constant.
×Ô¶¯½ÚÄÜÔËÐÐAutomatic energy saving operation
¸ù¾Ý¸ºÔØÇé¿ö£¬×Ô¶¯ÓÅ»¯V/FÇúÏߣ¬ÊµÏÖ½ÚÄÜÔËÐÐAccording to the load situation, the automatic optimization of V/F curve, to achieve energy saving operation
×Ô¶¯ÏÞÁ÷Automatic current limit
¶ÔÔËÐÐÆÚ¼äµçÁ÷×Ô¶¯ÏÞÖÆ£¬·ÀֹƵ·±¹ýÁ÷¹ÊÕÏÌøÕ¢
Automatic current limit on the operation period to prevent frequent over current fault trip
¶¨³¤¿ØÖÆ
Fixed length control
µ½´ïÉ趨³¤¶Èºó±äƵÆ÷Í£»ú the inverter stop after reach the set length
ͨѶ¹¦ÄÜCommunication function
¾ßÓÐRS485±ê׼ͨѶ½Ó¿Ú£¬Ö§³ÖASCIIºÍRTUÁ½ÖÖ¸ñʽµÄMODBUSͨѶÐÒé¡£¾ßÓÐÖ÷´Ó¶à»úÁª¶¯¹¦ÄÜ
With RS485 standard communication interface, support for ASCII and MODBUS two format of the RTU communication protocol. With master-slave multi machine linkage function
ÔËÐй¦ÄÜOperating function
ÔËÐÐÃüÁîͨµÀRun command channel
²Ù×÷Ãæ°å¸ø¶¨£»¿ØÖƶË×Ó¸ø¶¨£»´®Ðпڸø¶¨£»¿ÉÈýÖÖ·½Ê½Çл»
Operator panel; control terminal given; serial port given; can be three ways to switch
ƵÂÊÉ趨ͨµÀFrequency setting channel
¼üÅÌÄ£ÄâµçλÆ÷¸ø¶¨£»¼üÅÌ¡ø¡¢¨‹¼ü¸ø¶¨£»¹¦ÄÜÂëÊý×Ö¸ø¶¨£»´®Ðпڸø¶¨£»¶Ë×ÓUP/DOWN¸ø¶¨£»Ä£Äâµçѹ¸ø¶¨£»Ä£ÄâµçÁ÷¸ø¶¨£»Âö³å¸ø¶¨£»×éºÏ¸ø¶¨£»¿É¶àÖÖ¸ø¶¨·½Ê½ËæÊ±Çл»
Keyboard analog potentiometer;Keyboard key ¡ø¡¢¨‹ given;Functional code digital given; serial port given; terminal UP/DOWN given; analog voltage given; analog current given; pulse given; combination given; can be a variety of ways to switch
¿ª¹ØÊäÈëͨµÀSwitch input channel
Õý¡¢·´×ªÖ¸Á8·¿É±à³Ì¿ª¹ØÁ¿ÊäÈ룬¿É·Ö±ðÉ趨35ÖÖ¹¦ÄÜ¡£
Positive and reverse instructions; 8 programmable switching input, can be set to 35 kinds of functions.
Ä£ÄâÊäÈëͨµÀAnalog input channel
2·ģÄâÐźÅÊäÈ룬4¡«20mA¡¢0¡«10V¿ÉÑ¡
2 analog signal input, 4 ~ 20mA, 0 ~ 10V optional
Ä£ÄâÊä³öͨµÀ
Analog output channel
Ä£ÄâÐźÅÊä³ö£¬ 4¡«20mA»ò0¡«10V¿ÉÑ¡£¬¿ÉʵÏÖÉ趨ƵÂÊ¡¢Êä³öƵÂʵÈÎïÀíÁ¿µÄÊä³öAnalog signal output, 4 ~ 20mA or 0 ~ 10V optional, can achieve the set frequency, output frequency and other physical output
¿ª¹Ø¡¢Âö³åÊä³öͨ µÀSwitch, pulse output channel
1·¿É±à³Ì¿ªÂ·¼¯µç¼«Êä³ö£»1·¼ÌµçÆ÷Êä³öÐźţ»1·0¡«20KHzÂö³åÊä³öÐźţ¬ÊµÏÖ¸÷ÖÖÎïÀíÁ¿Êä³ö
1 programmable open collector output; 1 way relay output signal; 1 0 ~ 20KHz pulse output signal to achieve a variety of physical output
²Ù×÷
Ãæ°åoperation panel
LEDÊýÂëÏÔʾLED digital display
¿ÉÏÔʾÉ趨ƵÂÊ¡¢Êä³öµçѹ¡¢Êä³öµçÁ÷µÈ²ÎÊý
Can display the set frequency, output voltage, output current and other parameters
Íâ½ÓÒDZíÏÔʾExternal instrument display
Êä³öƵÂÊ¡¢Êä³öµçÁ÷¡¢Êä³öµçѹÏÔʾµÈÎïÀíÁ¿ÏÔʾ
Output frequency, output current, output voltage and other physical display
°´¼üËø¶¨Key lock
ʵÏÖ°´¼üµÄÈ«²¿Ëø¶¨
To achieve all of the lock button
²ÎÊý¿½±´Parameter copy
ʹÓÃÔ¶¿Ø¼üÅÌ¿ÉÒÔʵÏֱ䯵Æ÷Ö®¼äµÄ¹¦ÄÜÂë²ÎÊý¿½±´¹¦ÄÜ¡£
Use the remote control keyboard can realize the copy function between the function parameter code converter.
±£»¤¹¦ÄÜProtection function
¹ýÁ÷±£»¤£»¹ýѹ±£»¤£»Ç·Ñ¹±£»¤£»¹ýÈȱ£»¤£»¹ýÔØ±£»¤µÈOver current protection; overvoltage protection; under voltage protection; over heat protection; overload protection
»·¾³environment
ʹÓó¡ËùUse place
ÊÒÄÚ£¬²»ÊÜÑô¹âÖ±É䣬ÎÞ³¾°£¡¢¸¯Ê´ÐÔÆøÌå¡¢ÓÍÎí¡¢Ë®ÕôÆûµÈIndoor, free from direct sunlight, dust, corrosive gases,oil mist, steam, etc.
º£²¨¸ß¶ÈAltitude
µÍÓÚ1000Ã×£¨¸ßÓÚ1000Ã×ʱÐè½µ¶îʹÓã©
Less than 1000m(Higher than 1000 m with derating)
»·¾³Î¶ÈAmbient temperature
£10¡æ¡«£«40¡æ
ʪ¶Èhumidity
СÓÚ90%RH£¬ÎÞ½á¶Less than 95% RH, non-condensing
Õñ¶¯Vibration
СÓÚ5.9Ã×/Ãë2£¨0.6G£©Less than 5.9m / s? (0.6g)
´æ´¢Î¶Èstorage temperature
£20¡æ¡«£«60¡æ
½á¹¹structure
·À»¤µÈ¼¶Protection level
IP20£¨ÔÚÑ¡ÓÃ״̬ÏÔʾµ¥Ôª»ò¼üÅ̵Ä״̬Ï£©
IP20 (in the state of the selected state display unit or keyboard)
ÀäÈ´·½Ê½Cooling mode
Ç¿ÖÆ·çÀäForced air cooling
°²×°·½Ê½Installation method
±Ú¹Òʽ£¬¹ñÄÚ°²×°Wall-mounted, cabinet installation
Ãæ°å²Ù×÷ͼ£º
ÍâÐγߴ磺
¹«Ë¾×Ü»ú£º020-28608999
¹«Ë¾´«Õ棺020-28008900